Q.51 Medium Control Systems
The gain margin of a system can be determined from the bode plot as:
A The frequency at which phase is -180°
B The magnitude at phase crossover frequency
C 1/magnitude at phase crossover frequency (in linear form)
D The frequency at which magnitude is 1
Correct Answer:  C. 1/magnitude at phase crossover frequency (in linear form)
EXPLANATION

Gain margin = 1/|G(jω)| at phase crossover frequency where phase = -180°. It indicates how much gain can be increased before instability.

Test
Q.52 Medium Control Systems
What does the Routh-Hurwitz criterion determine?
A The bandwidth of the system
B The stability of a linear system without finding poles
C The steady-state error of the system
D The transient response of the system
Correct Answer:  B. The stability of a linear system without finding poles
EXPLANATION

Routh-Hurwitz criterion is used to determine the stability of a system by examining the characteristic equation coefficients without calculating poles.

Test
Q.53 Medium Control Systems
What is the steady-state error for a unit step input to a Type 0 system?
A Zero
B Infinity
C 1/(1 + Kp)
D 1/Kp
Correct Answer:  C. 1/(1 + Kp)
EXPLANATION

For Type 0 system with unit step input, e_ss = 1/(1 + Kp) where Kp is the position error constant.