Q.171 Medium Control Systems
What is the steady-state error for a unit step input to a Type 0 system?
A Zero
B Infinity
C 1/(1 + Kp)
D 1/Kp
Correct Answer:  C. 1/(1 + Kp)
EXPLANATION

For Type 0 system with unit step input, e_ss = 1/(1 + Kp) where Kp is the position error constant.

Test
Q.172 Medium Power Systems
In a three-phase power system with balanced conditions, the zero-sequence current flows through:
A The neutral conductor and ground path
B Only phase conductors
C Only the power transformer primary
D Generator neutral exclusively
Correct Answer:  A. The neutral conductor and ground path
EXPLANATION

Zero-sequence currents (equal in all three phases and same direction) require a return path through neutral or ground.

Test
Q.173 Medium Power Systems
Which of the following is a measure of power quality as per Indian Standards (IS 16001:2017)?
A Voltage harmonics THD and flicker
B Only frequency variation
C Only voltage magnitude variation
D Active power consumption rate
Correct Answer:  A. Voltage harmonics THD and flicker
EXPLANATION

IS 16001:2017 defines power quality parameters including THD (Total Harmonic Distortion) and voltage flicker limits.

Test
Q.174 Medium Power Systems
In load flow analysis, which bus type is used to specify active power and voltage magnitude?
A PV (Generator) bus
B PQ (Load) bus
C Slack bus
D Floating bus
Correct Answer:  A. PV (Generator) bus
EXPLANATION

PV buses represent generators where active power injection and voltage magnitude are specified; reactive power is calculated.

Test
Q.175 Medium Power Systems
Power system harmonics in Indian grids are primarily caused by:
A Non-linear loads such as power electronic converters and rectifiers
B Only transformer magnetizing current
C Synchronous motor starting
D Transmission line corona discharge exclusively
Correct Answer:  A. Non-linear loads such as power electronic converters and rectifiers
EXPLANATION

Modern non-linear loads like switch-mode power supplies, VFDs, and renewable energy inverters are major sources of harmonics in contemporary Indian grids.

Test
Q.176 Medium Power Systems
What is the primary cause of voltage instability in a power system?
A Excessive reactive power demand exceeding supply capacity
B High active power only
C Low frequency operation
D Transformer saturation alone
Correct Answer:  A. Excessive reactive power demand exceeding supply capacity
EXPLANATION

Voltage instability occurs when reactive power demand cannot be met, causing voltage collapse, particularly at weak points in the grid.

Test
Q.177 Medium Power Systems
The reactive power generated by an over-excited synchronous generator is:
A Negative (absorbed from the system)
B Positive (supplied to the system)
C Zero
D Depends on load current only
Correct Answer:  B. Positive (supplied to the system)
EXPLANATION

Over-excitation increases the magnetic field, causing the generator to supply lagging reactive power to support system voltage.

Test
Q.178 Medium Power Systems
A synchronous motor operating at no-load consumes:
A Only active power
B Only reactive power
C Both active and reactive power equally
D Zero power
Correct Answer:  B. Only reactive power
EXPLANATION

At no-load, a synchronous motor supplies only magnetizing current (reactive power) to maintain the magnetic field.

Test
Q.179 Medium Power Systems
Which protective relay is used for phase-to-phase fault detection in transmission lines?
A Instantaneous overcurrent relay
B Differential relay
C Under-frequency relay
D Directional overcurrent relay
Correct Answer:  B. Differential relay
EXPLANATION

Differential relays compare currents at both ends of a line and trip if there is a mismatch indicating an internal fault.

Test
Q.180 Medium Power Systems
The per-unit (p.u.) system in power systems is used primarily to:
A Convert all quantities to a common base for easier comparison and calculation
B Measure only reactive power
C Determine transformer losses
D Calculate mechanical power only
Correct Answer:  A. Convert all quantities to a common base for easier comparison and calculation
EXPLANATION

Per-unit system normalizes all quantities relative to chosen base values, simplifying analysis and comparison across different voltage levels and equipment ratings.

Test